Los Alamos
National Labs Tests
the HD-Rosetta
Los Alamos Labs
tested the HD-Rosetta and issued the following report:
Los Alamos National
Laboratory, an affirmative action/equal opportunity employer, is operated
by the University of California for the U.S. Department of Energy under
contract W-7405-ENG-36. By acceptance of this article, the publisher recognizes
that the U.S. Government retains a nonexclusive, royalty-free license
to publish or reproduce the published form of this contribution, or to
allow others to do so, for U.S. Government purposes. The Los Alamos National
Laboratory requests that the publisher identify this article as work performed
under the auspices of the U.S. Department of Energy. Los Alamos National
Laboratory strongly supports academic freedom and a researcher’s right
to publish; therefore, the Laboratory as an institution does not endorse
the viewpoint of a publication or guarantee its technical correctness.
Please note: Because of limitation involved with preparing images
for the Web, the images in this document are not as sharp as in the original.
A Survey of the
Environmental Degradation Resistance of
the HD-Rosetta
Data Storage Disc
LA-UR-99-0441
January 31, 1999
Jennifer A. Lillard
Materials Science and Technology Division
Los Alamos National Laboratory
Los Alamos, NM 87545
Abstract
The HD-Rosetta
data storage disc exhibited good degradation resistance in elevated temperature
air and a low corrosion rate in several aqueous environments. The disc
examined, which contained thousands of pages of analog data in the form
of microscopic images and text, was composed of a thin layer of nickel
on a silicon substrate. The text was formed from a master during deposition
of the nickel layer. Elevated temperature air was used to simulate fire
conditions, and aqueous corrosion testing simulated several scenarios
that could occur with a loss of the controlled storage environment. For
temperatures up to 300 oC (570 oF) and times up
to 65 h in laboratory air, the text remained readable. Exposures to saltwater,
tap water, and a simulated marine air environment for 15 weeks did not
affect readability of the text. The corrosion rate was measured as a function
of time for seven days and was approximately 1 mm
per year, which suggested that the disc could survive a long time in the
saltwater if the environmental conditions remained the same. However,
these results cannot be extrapolated to very long times because chemical
changes in the environment that may take place with time were not taken
into account.
Background
The objective of this work is to examine the environmental
degradation resistance of HD-Rosetta* discs,
which are intended to provide long-term analog (image) data storage. Each
disc is 2.2 inches in diameter and contains approximately 9000 pages of
text or images. The discs are made by covering a silicon wafer substrate
with a thin (~400 mm) layer of nickel. The
nickel layer, which contains the text, is formed from a master disc using
an electroforming process. The height of the lines that make up the letters
and images on the master disc is very small, less than about 100 nm.
The results presented below simulate two possible scenarios:
(1) fire conditions and (2) corrosive conditions that could arise in the
case of a flood or if control of the storage atmosphere was lost. Heat
treatment in air and aqueous exposure tests were used to simulate the
two scenarios. Electrochemical testing was performed to measure the corrosion
rate of the disc in saltwater.
Experimental
Test Disc
The disc provided was a "mother" from Sanyo/Verbatim
(#4). "Mother" indicates that the lines of text and images are
recessed into the nickel layer. The disc was shiny and silver in color.
Pages of text were visible to the naked eye as whitish rectangles on the
disc. The text sequence was the first six pages of the Bible followed
by a test pattern. This sequence was repeated over approximately half
of the disk; the other half was blank. Experiments were conducted on portions
of the disc that contained pages of text.
Sample Preparation
Samples were cut from the test disc using a slow speed
saw that was cooled with a water-soluble cutting fluid. The disc was mechanically
clamped at the edges, which did not contain text, and a diamond wafering
blade was used to cut rectangular samples that were approximately 3 mm
by 4 mm. Each sample was ultrasonically cleaned in three solutions: (1)
mild soap solution for 10 minutes, (2) distilled water for 10 minutes,
and (3) ethanol for 5 minutes. The samples were removed from solution
using tweezers and dried with clean, compressed gas. Samples were then
stored in airtight containers and examined under an optical microscope
for cleanliness before testing.
Metric
Degradation was measured using several metrics. The first
was overall appearance of the disc (e.g., visible oxidation of
surface). Second, the text was examined optically at 400x magnification
for microscopic damage and 1000x magnification for readability. Finally,
scanning electron microscope (SEM) images were taken at higher magnifications
to look for small changes in the text and test pattern.
Corrosion Resistance
Samples were exposed to saltwater, tap water, and a simulated
marine air environment to qualitatively examine the corrosion resistance.
The saltwater was a solution of 3.5 % by weight sodium chloride made with
distilled water, and the tap water was drawn from a tap at Los Alamos
National Laboratory. For each environment, approximately 50 ml of solution
was poured into a clean plastic 250-ml jar. A test sample was placed at
the bottom of the jar, and the jar was sealed. Marine air was simulated
by pouring 50 ml of the saltwater into a jar, placing a smaller plastic
container at the bottom of the jar, and setting a test sample on top of
the smaller container so that it was exposed to the air but not the solution.
The jar was then tightly sealed. A total of nine jars were prepared, three
for each environment. The jars were left in the laboratory and samples
were examined periodically.
The polarization resistance method was used to calculate
the corrosion rate of a disc sample exposed to salt water. This method
relies on the fact that, at a given applied current, the degree of polarization
is greater for a lower corrosion rate, and it is widely accepted due to
the correlation between the theory and experimental observations . The
polarization resistance was measured experimentally using the linear polarization
technique, which is non-destructive. A detailed description of the experimental
technique and derivation of the equations are given in Jones . Errors
due to uncertainty in Tafel constants and nonlinearity of polarization
curves were not accounted for because these errors were not expected significantly
change the result . The tests were performed on a 0.3 cm2 sample
in the 3.5 % sodium chloride solution under quiescent exposure to air.
High-Temperature Oxidation Resistance
An air furnace was used to simulate high-temperature conditions
that might be encountered in a fire situation. Samples were heated to
temperatures ranging from 100 oC (210 oF) to 550
oC (1000 oF) for times ranging from 24 h to 65 h.
Results
High-Temperature Oxidation
At temperatures of 100 oC (210 oF)
and 300 oC (570 oF) there was little or no degradation
of the disc for exposures up to the longest test time of 65 h. The sample
surfaces remained shiny and in some cases had a gold tint. In all cases,
the rectangles representing the pages of text were clearly visible.
Optical microscopy at 1000x magnification (Figure 1) showed
little difference between an as-received sample and one exposed to air
at 300 oC (570 oF) for 24 h. There were small changes
in the coloration of the surface and some of the letters in the heat-treated
sample, but these changes did not affect the readability of any of the
text. This observation was confirmed by SEM examination, which revealed
that the text and test patterns were practically identical for the two
test conditions. Figure 2 shows an SEM image of the text at 20,000x magnification.
At this magnification the sample exposed to 300 oC (570 oF)
air for 24 h shows small spots on the letters, which may or may not be
due to the heat treatment. However, the spots do not affect the readability
and the edges of the letters do not appear to be rougher than the as-received
sample. Pictures of the smallest test pattern are shown at 4500x magnification
in Figure 3. There is no perceptible difference in the pattern for the
as-received and heat-treated samples. The bulk surface of the heat-treated
sample looks slightly different than that of the as-received sample, and
it appears that some of the grain structure is visible.

(a)
(b)
Figure 1. Optical micrographs (1000x magnification)
comparing the readability of text for (a) an as-received sample
and (b) one exposed to air at 300 oC (570 oF)
for 24 hours.

(a)
(b)
Figure 2. Scanning electron micrographs show that
there is little difference in the quality of the text at 20,000x magnification
for (a) an as-received sample and (b) a sample exposed to
air at 300 oC (570 oF) for 24 hours.

(a)

Figure 3. Scanning electron micrographs showing
that there is no apparent difference in the quality of the smallest test
pattern at 4500x magnification for (a) an as-received sample and
(b) one exposed to air at 300 oC (570 oF)
for 24 hours.
A sample exposed at 300 oC (570 oF)
for 65 h showed significant discoloration on some areas of the sample
surface. At 20,000x magnification, very small patches (about 200 nm diameter)
were observed at the edges of a small percentage of the letters. The patches
were likely an oxide that resulted from the reaction of nickel with the
oxygen in air at 300 oC (570 oF). All of the text
was still readable as shown in Figure 4.

(a)

Figure 4. Scanning electron micrographs of a sample
exposed to air at 300 oC (570 oF) for 65 hours show
that (a) in some areas the text appears pristine and (b)
in areas with discoloration, the discoloration of the sample does not
affect the readability of the text.
Readily observable degradation occurred when samples were
exposed to air at 450 oC (840 oF) and 550 oC
(1020 oF) for 24 h. During the 450 oC (840 oF)
exposure an oxide formed on a few areas of the sample and destroyed the
text in those areas. In regions not covered by the oxide, the text and
test patterns were easily readable (Figure 5). After the 550 oC
(1020 oF) exposure, an oxide layer covered most of the surface.
Individual pages of text were visible to the naked eye, but the letters
were unreadable under microscopic examination. In an inert, oxygen-free
atmosphere, oxidation of nickel would be suppressed and degradation would
be dominated by diffusion of nickel atoms to produce grain growth and
smearing of the letters. Therefore, it would be expected that higher temperatures
and longer times could be tolerated in an inert environment.

Figure 5. Scanning electron micrograph of a sample
exposed to air at 450 oC (840 oF) for 24 hours shows
that the formation of an oxide layer renders parts of the text unreadable.
Corrosion
Samples were removed from the saltwater, tap water, and
simulated marine air environments after 1, 2, and 15 weeks of exposure
and then examined. Optical and scanning electron microscopy showed that
none of the samples had corrosion pits and that the only discernable change
in the quality of the text was a small amount of roughening of the bottom
surface of the letters. Figure 6 shows SEM micrographs taken after 15
weeks of exposure for the marine air environment. The condition shown
in Figure 6 is representative of the condition of the samples exposed
to saltwater and tap water.


Figure 6. SEM micrographs of the disc sample exposed
to the marine air environment showing that little degradation was observed
for a 15-week exposure. The micrographs shown are representative of the
condition of the samples exposed to saltwater and tap water.
The corrosion rate as a function of time, which was determined
using the linear polarization resistance (LPR) method, is shown in Figure
7. The corrosion rate represents the thickness of material that is corroded
away from the surface of the sample per year. Overall, the corrosion rate
was low. During the first few days, the corrosion rate decreased and then
stabilized to a value of less than 1 mm per
year (mmPY). Near the end of the test, at approximately
7 days, the corrosion rate increased slightly, which may indicate that
the long-term corrosion rate is somewhat higher. The LPR results, as well
as microscopic observations from the exposure tests, suggest that corrosion
of the bulk surface and the text occur at similar rates. If the corrosion
rate were 1 mmPY on the bulk surface but close
to zero at the text, the text would become unreadable within several days
because the depth of the text is very small. Furthermore, if the text
corroded at a much higher rate than the bulk surface, the edges of the
text would likely become distorted. Assuming that the 7-day test represents
equilibrium conditions with a corrosion rate of 1 mmPY
in salt water and assuming the thickness of the nickel layer is uniformly
400 mm, the text should remain readable for
400 years. However, the assumption that the 7-day test represents equilibrium
is overly optimistic. With time, the solution chemistry (e.g.,
pH) will likely change, and localized corrosion processes, such as crevice
corrosion and pitting, may occur. Also, condensation and evaporation in
a moist air environment will increase the corrosion rate.
Summary
The HD-Rosetta, an analog, data storage disc, was resistant
to degradation at moderate temperatures in stagnant air. At times up to
65 h, little or no degradation occurred for temperatures up to 300
oC (570 oF). At 450 oC (840 oF)
and higher oxidation of the nickel surface occurred, which rendered parts
of the text unreadable. If the discs were stored in an inert gas atmosphere,
it is expected that they would resist degradation at temperatures above
300 oC (570 oF).
Results of exposure and electrochemical tests indicate
that the HD-Rosetta disc had a high resistance to corrosion in saltwater,
tap water, and marine air. After 15 weeks of exposure no pitting was observed
for any of the environments, and the text appeared almost pristine. The
corrosion rate n 3.5% sodium chloride, as calculated by linear polarization
resistance during a 7-day test, was on the order of 1 mm
per year. Extrapolation of the corrosion results to very long times is
not prudent because chemistry changes in the environment may cause localized
corrosion.
References 1.
Stern, M. and A.L. Geary, J. Electrochem. Soc., 1957. 104: p. 56.
2. Stern, M., Corrosion, 1958. 14: p. 440t.
3. Wagner, C.W. and W. Traud, Z. Elektrochem., 1938. 44: p. 391.
4. Simmons, E.J., Corrosion, 1955. 11: p. 255t.
5. Skold, R.V. and T.E. Larsen, Corrosion, 1957. 13: p. 139t.
6. Bonhoeffer, K.F. and W. Jena, Z. Elektrochem., 1951. 55: p. 151.
7. Jones, D.A., in Principles and Prevention of Corrosion. 1996, Simon
& Schuster: Upper Sadle River, NJ. pp. 143-165.
8. Stern, M. and E.D. Weisert, Proc. ASTM, 1959. 32: p. 1280.
|